HLS-2CUA

HLS-2CUA
Part code: HLS-2CUA

The HLS-2CUA provides localised induction loop facility to help individuals with hearing loss access information from public announcements, help & information points and intercom systems.

The HLS-2CUA is a combination of the HLS-2C active loop panel and the HLS-UA power and input adapter.

The HLS-UA includes an AC mains power supply  (110 V  / 230 V AC) providing a 24 V DC output and an input signal adapter to connect from 100 V line PA to a level suitable for the HLS-2C.
When correctly mounted, and with appropriate cable glands, the enclosure can provide IP65 protection to the power supply and signal input adapter.

hidden tab
Features
  • Robust design
  • Compliment intercom panel
  • Simple integration & installation
  • Low power consumption
  • Class D efficiency
  • DSP for unrivaled intelligibility
  • Prides a localised magnetic field
  • Low lifetime cost
  • Excellent reliability, 5 year warranty & free technical support
  • Power supply (110 V  / 230 V AC)
  • Transformer isolated inputs
  • Metal loss correction
Standards

Safety, EMC

The HLS-2C and HLS-UA is CE marked to indicate compliance with relevant product safety and EMC standards.

Loop Performance

The HLS-2C will allow an Audio Frequency Induction Loop system that meets the requirements of IEC 60118-4 to be created at the expected height and distance of a single user, if the system is specified, installed and commissioned
in an appropriate manner, including observing Ampetronic instructions.

Specifications (PDF)

Click here to open datasheet in a new tab

HLS-2CUA
  • Robust design
  • Compliment intercom panel
  • Simple integration & installation
  • Low power consumption
  • Class D efficiency
  • DSP for unrivaled intelligibility
  • Prides a localised magnetic field
  • Low lifetime cost
  • Excellent reliability, 5 year warranty & free technical support
  • Power supply (110 V  / 230 V AC)
  • Transformer isolated inputs
  • Metal loss correction
INPUTS
Mains power supply Supply voltage range: 90-264 VAC
Supply voltage frequency: 47-63 Hz
Connector: Fused screw terminal, 0.5 – 2.5 mm2 solid core or untinned fine stranded
wire
Fuse: 1 AT (spare supplied)
Power Consumption: 110 mA continuous sine
70 mA continuous pink noise
30 mA quiescent
Isolation (60 s): 3 kV (input/output)
1.5 kV (input/case)
0.5 kV (output/case)
Audio input Voltage: 100 VAC max
Connector: Wago cage clamp, 0.1 – 2.5 mm2 solid core or untinned fine stranded wire
Isolation: 5.5 kV (6.5 kV for 1 sec)

 

OUTPUTS
Audio output to HLS-2C Voltage: 1 VAC nominal
-40 dB relative to audio input
Connector: Wago cage clamp, 0.2 – 0.75 mm2 solid core or untinned fine stranded
wire twisted pair (Note 1)
DC output to HLS-2C Voltage: 24 VDC nominal
Power Consumption: 15 W max
Connector: Wago cage clamp, 0.5 – 1.5 mm2 solid core or untinned fine stranded
wire (Note 1)
Environmental Operating temperature: -20 to +70 °C
Humidity (non condensing): 90 % RH max
Physical Dimensions width 150 mm x length 200 mm x depth 82 mm
Weight 2 kg

 

Note 1: Wire size range specified to match terminals of both HLS-2C and the HLS-UA products.

 

Safety, EMC

The HLS-2C and HLS-UA is CE marked to indicate compliance with relevant product safety and EMC standards.

Loop Performance

The HLS-2C will allow an Audio Frequency Induction Loop system that meets the requirements of IEC 60118-4 to be created at the expected height and distance of a single user, if the system is specified, installed and commissioned
in an appropriate manner, including observing Ampetronic instructions.

hidden tab
Features
  • Robust design
  • Compliment intercom panel
  • Simple integration & installation
  • Low power consumption
  • Class D efficiency
  • DSP for unrivaled intelligibility
  • Prides a localised magnetic field
  • Low lifetime cost
  • Excellent reliability, 5 year warranty & free technical support
  • Power supply (110 V  / 230 V AC)
  • Transformer isolated inputs
  • Metal loss correction
Standards

Safety, EMC

The HLS-2C and HLS-UA is CE marked to indicate compliance with relevant product safety and EMC standards.

Loop Performance

The HLS-2C will allow an Audio Frequency Induction Loop system that meets the requirements of IEC 60118-4 to be created at the expected height and distance of a single user, if the system is specified, installed and commissioned
in an appropriate manner, including observing Ampetronic instructions.

Specifications (PDF)

Click here to open datasheet in a new tab

Book a demonstration

For more information on these products or any other requirement you may have, please complete the form or call us on +44 (0) 1636 610062

Case studies

Sorry, No posts.

Sectors and applications

Sorry, No posts.

Click here to contact us for more information