HLS-2CUA
The HLS-2CUA provides localised induction loop facility to help individuals with hearing loss access information from public announcements, help & information points and intercom systems.
The HLS-2CUA is a combination of the HLS-2C active loop panel and the HLS-UA power and input adapter.
The HLS-UA includes an AC mains power supply (110 V / 230 V AC) providing a 24 V DC output and an input signal adapter to connect from 100 V line PA to a level suitable for the HLS-2C.
When correctly mounted, and with appropriate cable glands, the enclosure can provide IP65 protection to the power supply and signal input adapter.
hidden tab
Features
- Robust design
- Compliment intercom panel
- Simple integration & installation
- Low power consumption
- Class D efficiency
- DSP for unrivaled intelligibility
- Prides a localised magnetic field
- Low lifetime cost
- Excellent reliability, 5 year warranty & free technical support
- Power supply (110 V / 230 V AC)
- Transformer isolated inputs
- Metal loss correction
Standards
Safety, EMC
The HLS-2C and HLS-UA is CE marked to indicate compliance with relevant product safety and EMC standards.
Loop Performance
The HLS-2C will allow an Audio Frequency Induction Loop system that meets the requirements of IEC 60118-4 to be created at the expected height and distance of a single user, if the system is specified, installed and commissioned
in an appropriate manner, including observing Ampetronic instructions.
Downloads
Specifications (PDF)
Click here to open datasheet in a new tab
- Robust design
- Compliment intercom panel
- Simple integration & installation
- Low power consumption
- Class D efficiency
- DSP for unrivaled intelligibility
- Prides a localised magnetic field
- Low lifetime cost
- Excellent reliability, 5 year warranty & free technical support
- Power supply (110 V / 230 V AC)
- Transformer isolated inputs
- Metal loss correction
INPUTS | ||
Mains power supply | Supply voltage range: | 90-264 VAC |
Supply voltage frequency: | 47-63 Hz | |
Connector: | Fused screw terminal, 0.5 – 2.5 mm2 solid core or untinned fine stranded wire |
|
Fuse: | 1 AT (spare supplied) | |
Power Consumption: | 110 mA continuous sine 70 mA continuous pink noise 30 mA quiescent |
|
Isolation (60 s): | 3 kV (input/output) 1.5 kV (input/case) 0.5 kV (output/case) |
|
Audio input | Voltage: | 100 VAC max |
Connector: | Wago cage clamp, 0.1 – 2.5 mm2 solid core or untinned fine stranded wire | |
Isolation: | 5.5 kV (6.5 kV for 1 sec) |
OUTPUTS | ||
Audio output to HLS-2C | Voltage: | 1 VAC nominal -40 dB relative to audio input |
Connector: | Wago cage clamp, 0.2 – 0.75 mm2 solid core or untinned fine stranded wire twisted pair (Note 1) |
|
DC output to HLS-2C | Voltage: | 24 VDC nominal |
Power Consumption: | 15 W max | |
Connector: | Wago cage clamp, 0.5 – 1.5 mm2 solid core or untinned fine stranded wire (Note 1) |
|
Environmental | Operating temperature: | -20 to +70 °C |
Humidity (non condensing): | 90 % RH max | |
Physical | Dimensions | width 150 mm x length 200 mm x depth 82 mm |
Weight | 2 kg |
Note 1: Wire size range specified to match terminals of both HLS-2C and the HLS-UA products.
Safety, EMC
The HLS-2C and HLS-UA is CE marked to indicate compliance with relevant product safety and EMC standards.
Loop Performance
The HLS-2C will allow an Audio Frequency Induction Loop system that meets the requirements of IEC 60118-4 to be created at the expected height and distance of a single user, if the system is specified, installed and commissioned
in an appropriate manner, including observing Ampetronic instructions.
hidden tab
Features
- Robust design
- Compliment intercom panel
- Simple integration & installation
- Low power consumption
- Class D efficiency
- DSP for unrivaled intelligibility
- Prides a localised magnetic field
- Low lifetime cost
- Excellent reliability, 5 year warranty & free technical support
- Power supply (110 V / 230 V AC)
- Transformer isolated inputs
- Metal loss correction
Standards
Safety, EMC
The HLS-2C and HLS-UA is CE marked to indicate compliance with relevant product safety and EMC standards.
Loop Performance
The HLS-2C will allow an Audio Frequency Induction Loop system that meets the requirements of IEC 60118-4 to be created at the expected height and distance of a single user, if the system is specified, installed and commissioned
in an appropriate manner, including observing Ampetronic instructions.
Specifications (PDF)
Click here to open datasheet in a new tab
Book a demonstration
For more information on these products or any other requirement you may have, please complete the form or call us on +44 (0) 1636 610062